Facility Features
Technical Facilities
- 15,000 gallon (357-bbl.) capacity water circulating system
- High-pressure remotely controlled choke manifold system, which includes five chokes of various manufacturers, and a process control system
- Two triplex pumps capable of 250 GPM and 500 GPM up to 5000 psi
- Gas flows up to 10,000SCFM at 5000 psi
- Safekick MPD choke system
- 2,800-ft. model well with two P/T gauge mandrels and a side pocket gas lift mandrel for production or drilling circulation
- 5,200-ft. model well with four downhole P/T gauge mandrels, two side-pocket gas lift
mandrels, and single/multimode fiber optics for performing DAS/DTS measurements.
- Fiber Optics:
- DAS (PureCore SMF fiber (9/125/155), E2000/APC terminated connection.
- DTS (0.5m measurement, 1E-3 F accuracy, 30 sec interval, WITSML output file)
- Fiber Optics:
- Nitrogen generator with 180,000scf of gas storage onsite.
- VPC flow loop for testing and API validation of both 1” and 1.5” gas lift valves.
- 40-ft. tower with inclinable beam for testing flow regimes at different inclinations and orientations in tubulars.
- 100-ft. derrick with 100-ft 12" vertical pipe
- Multiphase flow loop capable of 1.5MMSCFD of gas and 200 GPM water
- PASON Rig Display and Driller's Station, Full WITS recording of instruments
- Data:
- 50TB RAID6 onsite storage
- 10Gbe network connectivity at control room and blue shed (RJ45, SFP+)
- Docker container platform for service hosting
- Automated offsite synchronization (RSYNC, RTR, AWS, Azure, OneDrive)
- WITSML stram from Pason for onsite 3rd party monitoring (1 sec, 10 sec)
- Two classrooms and a computer simulator classroom
Keller Classroom Building
- Classroom has 2 projectors, 2 flat screens, 2 Da-Lite projector screens, digital media presentation system and seats 50
- Computer lab has 10 computer stations, Eno projector, 4 flat screens, and a digital presenter